  • I have installed an N/C Alarm push button. How do I program the DAU to accept a N/C alarm input?

    This can be programmed in the Avire Hub or by sending an SMS to the Avire DCP to change this parameter, by sending the following code (you will need to know the telephone number of the DCP):

    Pin1234, space P117, space 1

    Please note that the four digits (Pin1234) are the pin code for the DCP.

  • How do I connect the DAU PIT Unit to the DCP (4G GSM Gateway)?

    An additional CAN wire connection is required from the DCP connector ‘J8’ to the DAU PIT.

    ‘SW4’ on the DCP will also need to be in the ‘OFF’ position.

    The cover on the DCP will need to be removed to gain access to the connector and switch.

  • I have successfully installed a Memcom+ with a DCP (4G GSM Gateway) and it is making call but I am unable to connect to it remotely

    It is possible the selected Codec is incorrect. The DCP Codec configuration P078 needs to be changed to ‘0’. This can be checked and programmed in the Avire Hub or by sending an SMS to the DCP to change this parameter, by sending the following code (you will need to know the telephone number of the DCP):

    Pin1234, space P078, space 0

    Please note that the four digits (Pin1234) are the pin code for the DCP.

  • What should I do if the DCP/DAU/PIT are not working?

    All CAN-enabled Avire products have an End of line (EOL) switch which is set as ‘ON’ by default in what condition would EOL be turned ‘OFF’?

    Using more than two CAN-enabled Avire products would require first and last device in the CAN line to remain ‘ON’ all others devices should be ‘OFF’

    E.g. 1 x DCP & 1 x DAU connected both EOL switched to ‘ON’

    1 x DCP, 1 x Lift Hawk and 1 x DAU connected the Lift Hawk should be EOL switched ‘OFF’

  • I have a Memcom+ connected to an Avire DCP with a non Avire SIM, do I need to change any settings on the DCP?

    Using a Non Avire Sim (EE, O2, Vodafone etc.) will not require setting changes on the DCP when using Memcom for only emergency calls, the exception would be when using to monitor on the Avire HUB then APN settings will need to be changed on the DCP by sending a SMS, (APN settings can be found on the SIM Network provider web site)


    e.g. text, Pin1234, P060 APN, P061 USR, P062 PASS (SEND)


    GiffGaff does not have a value after ‘P062’

  • I have an Avire DCP with an Avire Sim connected to a Memcom+, do I need to change any settings on the DCP?

    No programming required, the DCP is also pre-programmed for Avire Sim APN settings.



  • What should I do if the external alarm push button is not working but the DAU has been installed correctly?

    The DAU requires the external Alarm Push buttons to be voltage free, if not you will need to wire a separate relay in circuit.



  • I have multiple DAU's on more than one lift car programmed to perform a background test call (also known as three day test calls), but the Avire Hub is not showing all units as successful?

    The CAN1 ID switch used for setting the lift shaft number may be duplicated. SW1 & SW 2 are used to set the correct lift shaft.


  • I keep hearing the DAU voice message 'wait a few minutes and try again'. Why is this happening?

    The DCP CAN bus connections may be reversed. Check that the CAN High and Low wires are correctly installed.

  • I'm unable to place a call or remotely connect to the DCP. What should I do?

    Check that the DCP settings have not changed from the pre-set Avire defaults. This can be checked and programmed in the Avire Hub or by sending an SMS to the DCP to change these parameters, by sending the following code (you will need to know the telephone number of the DCP):

    Pin1234, space P014, space 7, space P046, space 100, P078, space 0

    Please note that the four digits (Pin1234) are the pin code for the DCP.

  • How do I mount a COP DAU?

    The DAU should be mounted to studs on the back the back of the COP panel.



  • How do I mount a pit phone?

    A PIT phone should be screwed to an accessible area of the wall in the PIT. It is recommended that it is mounted in the refuge space.